IF97 region 1: współczynniki energii Gibbsa
Źródło: IAPWS, Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam, R7-97(2012), strony PDF: 7. Podpis w źródle: Table 2. Numerical values of the coefficients and exponents of the dimensionless Gibbs free energy for region 1, Eq. (7)
Współczynniki równania podstawowego regionu 1 IF97 dla cieczy sprężonej i podchłodzonej.
Pokazano 34 z 34 wierszy.
| i | I | J | n |
|---|---|---|---|
| 1 | 0 | -2 | 0.14632971213167 |
| 2 | 0 | -1 | -0.84548187169114 |
| 3 | 0 | 0 | -3.756360367204 |
| 4 | 0 | 1 | 3.3855169168385 |
| 5 | 0 | 2 | -0.95791963387872 |
| 6 | 0 | 3 | 0.15772038513228 |
| 7 | 0 | 4 | -0.016616417199501 |
| 8 | 0 | 5 | 0.00081214629983568 |
| 9 | 1 | -9 | 0.00028319080123804 |
| 10 | 1 | -7 | -0.00060706301565874 |
| 11 | 1 | -1 | -0.018990068218419 |
| 12 | 1 | 0 | -0.032529748770505 |
| 13 | 1 | 1 | -0.021841717175414 |
| 14 | 1 | 3 | -5.283835796993 |
| 15 | 2 | -3 | -0.00047184321073267 |
| 16 | 2 | 0 | -0.00030001780793026 |
| 17 | 2 | 1 | 4.7661393906987 |
| 18 | 2 | 3 | -4.4141845330846 |
| 19 | 2 | 17 | -7.2694996297594 |
| 20 | 3 | -4 | -3.1679644845054 |
| 21 | 3 | 0 | -2.8270797985312 |
| 22 | 3 | 6 | -8.5205128120103 |
| 23 | 4 | -5 | -2.2425281908 |
| 24 | 4 | -2 | -6.5171222895601 |
| 25 | 4 | 10 | -1.4341729937924 |
| 26 | 5 | -8 | -4.0516996860117 |
| 27 | 8 | -11 | -1.2734301741641 |
| 28 | 8 | -6 | -1.7424871230634 |
| 29 | 21 | -29 | -6.8762131295531 |
| 30 | 23 | -31 | 1.4478307828521 |
| 31 | 29 | -38 | 2.6335781662795 |
| 32 | 30 | -39 | -1.1947622640071 |
| 33 | 31 | -40 | 1.8228094581404 |
| 34 | 32 | -41 | -9.3537087292458 |