IF97 region 1: wartości testowe
Źródło: IAPWS, Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam, R7-97(2012), strony PDF: 9. Podpis w źródle: Table 5. Thermodynamic property values calculated from Eq. (7) for selected values of T and p
Punkty kontrolne regionu 1 IF97 do weryfikacji implementacji równania podstawowego.
Pokazano 18 z 18 wierszy.
| Punkt | T [K] | p [MPa] | rho [kg/m3] | Wielkość | Wartość | Jednostka |
|---|---|---|---|---|---|---|
| T300-p3 | 300 | 3 | v | 0.00100215168 | m3/kg | |
| T300-p3 | 300 | 3 | h | 115.331273 | kJ/kg | |
| T300-p3 | 300 | 3 | u | 112.324818 | kJ/kg | |
| T300-p3 | 300 | 3 | s | 0.392294792 | kJ/(kg K) | |
| T300-p3 | 300 | 3 | cp | 4.17301218 | kJ/(kg K) | |
| T300-p3 | 300 | 3 | w | 1507.73921 | m/s | |
| T300-p80 | 300 | 80 | v | 0.000971180894 | m3/kg | |
| T300-p80 | 300 | 80 | h | 184.142828 | kJ/kg | |
| T300-p80 | 300 | 80 | u | 106.448356 | kJ/kg | |
| T300-p80 | 300 | 80 | s | 0.368563852 | kJ/(kg K) | |
| T300-p80 | 300 | 80 | cp | 4.01008987 | kJ/(kg K) | |
| T300-p80 | 300 | 80 | w | 1634.69054 | m/s | |
| T500-p3 | 500 | 3 | v | 0.001202418 | m3/kg | |
| T500-p3 | 500 | 3 | h | 975.542239 | kJ/kg | |
| T500-p3 | 500 | 3 | u | 971.934985 | kJ/kg | |
| T500-p3 | 500 | 3 | s | 2.58041912 | kJ/(kg K) | |
| T500-p3 | 500 | 3 | cp | 4.65580682 | kJ/(kg K) | |
| T500-p3 | 500 | 3 | w | 1240.71337 | m/s |