IF97 region 1: testy równania T(p,s)
Źródło: IAPWS, Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam, R7-97(2012), strony PDF: 12. Podpis w źródle: Table 9. Temperature values calculated from Eq. (13) for selected values of p and s
Punkty kontrolne równania wstecznego T(p,s) w regionie 1.
Pokazano 3 z 3 wierszy.
| Punkt | p [MPa] | s [kJ/(kg K)] | T [K] |
|---|---|---|---|
| p3-s0_5 | 3 | 0.5 | 307.842258 |
| p80-s0_5 | 80 | 0.5 | 309.979785 |